Share

Anterior cruciate ligament reconstruction by using bioabsorbable femoral cross pins: MR imaging findings at follow-up and comparison with clinical findings.

Authors

Studler U, White LM, Naraghi AM, Tomlinson G, Kunz M, Kahn G, Marks P.

Department of Medical Imaging, Mount Sinai Hospital and University Health Network, University of Toronto, Toronto, Ontario, Canada. studleru@uhbs.ch

Abstract

PURPOSE:

To determine the frequency of imaging findings and complications related to bioabsorbable femoral cross pins at follow-up magnetic resonance (MR) imaging studies after anterior cruciate ligament (ACL) reconstruction and compare these MR imaging findings with clinical evaluation findings. MATERIALS AND

METHODS:

The institutional review board approved this retrospective study, and informed consent was waived. Follow-up MR imaging studies (average, 26 months after surgery) in 218 patients with prior ACL reconstruction were retrospectively reviewed. Cross-pin fracture, posterior transcortical breach, migration, resorption, and lateral prominence of cross pins, as well as the cross-pin angle relative to the transepicondylar line, were investigated on MR images. The clinical evaluation included Lachman, anterior drawer, and pivot shift tests, as well as assessment for joint tenderness.

RESULTS:

Fracture, posterior transcortical breach, migration, and lateral prominence of cross pins were excluded from analysis when at least one cross pin was completely resorbed (n = 16 patients). Forty-five fractured cross pins were seen in 35 (17%) of 202 patients. The posterior femoral cortex was breached in 57 (28%) of 202 patients. Migration of fractured pin fragments occurred in 12 (6%) of 202 patients. There was a significant relationship between fractures and posterior breach of cross pins (P = .001), as well as between cross-pin angles and fractures (P = .002). Both cross pins were completely resorbed in 12 (6%) of 218 patients (average time since surgery, 53 months; range, 8-92 months). No significant association was found between any MR imaging finding related to cross pins and clinical test findings.

CONCLUSION:

Fracture and posterior transcortical breach of bioabsorbable femoral cross pins, commonly seen at follow-up MR imaging studies, do not correlate with clinical findings of joint instability or pain. Posteriorly angulated cross pins and posterior transcortical breach are significantly associated with cross-pin fractures.

References

  • Studler U, White LM, Naraghi AM, Tomlinson G, Kunz M, Kahn G, Marks P. Anterior cruciate ligament reconstruction by using bioabsorbable femoral cross pins: MR imaging findings at follow-up and comparison with clinical findings. Radiology. 2010;255;1
  • PubMed id : 20308449
  • doi : 10.1148/radiol.09091119

Link to pubmed | Link to Google Scholar | Link to full text publication

2010


Radiology


Back to HepaTop


Due mainly to homonyms, errors are possible and if you detect "false positives" or "false negatives" don't be too frustrated and please contact the webmaster.